Common Power System Issues in Colocation Facilities


Overview:

To ensure the power system in a colocation facility can withstand both power and equipment failures, focus on two key principles: capacity and redundancy.

Key Points:

- Capacity: Ensuring that equipment is not overburdened.
- Redundancy: Having backup systems to take over in case of failure.

Common Issues:


1. Lack of Redundant Power Grids

Colocation facilities should have multiple Power Distribution Units (PDUs) connected to separate power grids. This setup ensures continuous operation even if one grid fails, keeping customer servers online without interruption.

2. Non-redundant Uninterruptible Power Supplies (UPS)

UPS units provide power during outages until generators activate. It's crucial to have multiple redundant UPS units in an n+1 configuration?"enough units plus an extra. This setup allows each UPS to run below capacity, preventing overloads during a failure. For instance:
- Two UPS units should each run below 50%.
- Three units should run below 66%.
- Four units should run below 75%.

3. Transfer Switch Failures

Many facilities use mechanical transfer switches, which are less reliable than circuit breakers, to shift power from the utility to the generator. These are common failure points, so redundant switches are necessary to maintain network uptime.

4. Insufficient Generator Capacity

Generators must be able to run at 1.5 times the total building load to avoid overloading. A backup generator should be available in case the primary one fails. It’s essential that facilities plan for seamless power switches between generators. Problems often arise because facilities expand capacity by adding more generators rather than integrating redundant systems. Generators must be well-maintained, tested monthly, and fully fueled.

Considerations:

Despite the importance of robust power systems for network uptime, fewer than 5% of colocation facilities are equipped with optimal setups. Without properly maintained and redundant components running below capacity, both network and equipment performance can suffer. Remembering "capacity and redundancy" is crucial for ensuring resilience against power and equipment failures.